Shenzhen HRD SCI&TECH CO.,Ltd

HRD UPS---Global High-end Power Solutions Expert! Your best trustable OEM/ODM power partner! ISO9001-2015,ISO14001 , ISO18001, TLC, CQC, TUV ,CE certified.

Manufacturer from China
Verified Supplier
17 Years
Home / Products / 3 Phase Online UPS /

Powerwell Max (America) series 3PHASE Online HF UPS 10 - 40Kva ,208 - 120Vac ,220 - 127Vac

Contact Now
Shenzhen HRD SCI&TECH CO.,Ltd
Visit Website
City:shenzhen
Province/State:guangdong
Contact Person:MrHunter Chen
Contact Now

Powerwell Max (America) series 3PHASE Online HF UPS 10 - 40Kva ,208 - 120Vac ,220 - 127Vac

Ask Latest Price
Video Channel
Place of Origin :Shenzhen Chian
Brand Name :HRD/ ODM/OEM
Certification :CE ,ISO9001:2008
Model Number :PWMA3310,PWMA3320,,PWMA3340
MOQ :5PCS
Price :2200USD-8000USD/PCS;
Packaging Details :1PCS/CTN with wooden case
Delivery Time :3weeks after down payment
Payment Terms :TT or LC at sight
Supply Ability :2000PCS/ month
Warranty :2 years after shipment
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Powerwell max (America) series 3PHASE Online HF UPS 10 - 40Kva ,208 - 120Vac ,220 - 127Vac

Introduction:Powerwell max (America)series 3 phase 10-40kva is a high end uninterruptible power supply, which has adopted the world leading electrical and electronic technology to increase performance and super high reliability(MTBT>200,000h).3nos high speed DSPs with completed digital control fully ensure highest quality of power supply and UPS reliabitly. Being kin to 1.0 input power factor and less than 2% THDi lead this UPS green and energy saving. It also offers humanization design: full front access of service ability, user- friendly touch screen.

Perfect Applications:

Internet Servor ,Middle Data Center, Medium-scale network system / computing center, bank and securities, business server group, Medium-scale office automation, precision equipment, etc.

Features: complete digital control technology

Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.

Excellent electrical properties

True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity;

High input power factor, green and energy-saving

Input end with PFC and input PF of the whole UPS up to 0.99,;

Dual AC input source supportable

Allowable AC and bypass 2 input ac source

Strong environmental adaptability

Wide input voltage and frequency range, adaptation to all kinds of climatic

and geographical environment;

Comprehensive protection measures

Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS;

IGBT and SCR adopts the advanced EUPEC power module;

The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter.

Similar modular design

Each phase main board are designed like rack for easy assembling and maintenance

Inbuilt battery pack plug-in design for easy use

Intelligent battery management (ABM)

Adopting the intelligent battery management:

Intelligent charger:interval three-stage charging process( constant current,constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work)

Back up time displayed on the LCD screen

Battery temperature compensation

Online detecting battery status,

The max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current;

Periodic self-test battery, detecting the battery problems timely;

With battery inverse connection, over voltage / current protection, to protect the battery;

Cold start and AC start Function

Directly start the UPS through battery or start UPS through Mains only.

Superior network monitoring capabilities

Communication port (RS232, SNMP card, RS485, Dry contact , and so on) ,

Easy-maintenance design

a) Adopts the full front maintenance design, reducing the restrictions

on the installation space, and saving the space of computing center;

b)Modular design class, convenient and easy site maintenance;

c) With manual maintain bypass,

d)Battery replacement without disrupting the UPS running;

e) Historical records search function, events up to1,000 items;

Friendly interface with Large LCD

Large LCD display and LED status indication; Abundant information display of UPS;

Technical Specifications:

Introduction:PWMA II series 3 phase 10-40kVA is transformer-less a high quality uninterruptible power supply, which has adopted the world leading electrical and electronic technology to increase performance and high reliability(MTBF>200,000h). Being kin to 1.0 input power factor and less than 4% THDi lead this UPS green and energy saving.

Perfect Applications:

Internet Servor, Small and Medium-scale network system / , Bank and Securities, Business server group, Precision equipment,Medical,Energy, etc.

Features: complete digital control technology

Fully digital control with DSP chip processor, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger etc.

Excellent electrical properties

True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity;

High input power factor, green and energy-saving

Input PF above 0.99 and efficiency up to 96%;

Output PF 1.0 with 3 level inverter technology

Strong load capability with high efficiency up to 96%

Strong environmental adaptability

Wide input voltage and frequency range, adaptation to all kinds of climatic and geographical environment

Comprehensive protection measures

The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter

Intelligent battery management (ABM)

Adopting the intelligent battery management:

Intelligent charger:interval three-stage charging process( constant current,constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work)

Online detecting battery status,

The max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current;

Periodic self-test battery, detecting the battery problems timely;

Cold start and AC start Function

Directly start the UPS through battery or start UPS through Mains only.

Superior network monitoring capabilities

Communication port (RS232, USB, and so on) connecting with computer,SNMP card optional,

Friendly interface LED indicators with 7inch touch screen Parallel up to 8 units

Technical specification:

Technical Specification:

Model PWMA3310II PWMA3315II PWA3320II PWMA3330II PWMA3340II
Mains Input
Rated Input Voltage 200/208/220VAC (Line-Line),3 Phases + Neutral + Ground
Rated Frequency 50/60Hz
Input Voltage Range 167~260Vac (Line-Line),full load;
125V~167Vac (Line-Line),load decreases linearly according to the min phase voltage
Input Frequency Range 40Hz~70Hz
Input Power Factor >0.99
Input Current THDi <3% (linear load),<5% (non-linear load)
Bypass Input
Rated Bypass Voltage 200/208/220VAC (Line-Line)
Rated Frequency 50/60Hz
Bypass Voltage Range Selectable, default -20%~+15%;
Upper limit: +10%, +15%, +20%, +25%;
Lower limit: -10%, -15%, -20%, -30%, -40%
Bypass Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload 125% Long term operation;125%~130% for 10min;
130%~150% for 1min;
Output
Rated Inverter Voltage 200/208/220VAC (Line-Line)
Rated Frequency 50/60Hz
Output Power Factor 1
Voltage precision ±1%(0-100% linear load)
Transient Response <5% for step load (20% - 100% -20%)
Transient recovery < 30ms for step load (20% - 100% -20%)
Output Voltage THDu <1% (linear load);<5% (non-linear load)
according to IEC/EN62040-3
Inverter Overload <110%, 60min;110%~125%,10min;
125%~150%,60s;>150% , 200ms
Frequency Regulation 50/60Hz±0.1%
Synchronized Range Settable, ±0.5Hz ~ ±5Hz, default ±3Hz
Synchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/s, default 0.5Hz/s
Battery And Charger
Battery Rate Voltage ±120VDC
Battery QTY 2*20PCS 12V*7AH/9AH(internal-battery) 4*20PCS 12V*7AH/9AH(internal-battery)
20PCS per strings,External battery
Charger Power Max=20% of System Power
Efficiency
Normal Operation 94%max
Battery Operation 93%max
System
Display 7inch touch screen
Interface

Standard: USB,RS232, RS485

Option: SNMP, Dry Contact, Parallel kit,Battery cold start

Environmental
Operation Temperature 0 ~ 40 ℃
Storage Temperature -40 ~ 70 ℃
Relative Humidity 0 ~ 95% (Non condensing)
Noise (1 meter) 58dB @ 100% load, 52dB @ 45% load 70dB @ 100% load, 62dB @ 45% load
Physical data
Dimension
(W*D*H,mm)
Internal-bat 250*830*710 350*825*1200
External-bat 250*530*660 250*785*650
Weight(Kg) Internal-bat 150 290
External-bat 45 54 67 73

Note:Any specification subject to change without notice;

Note:Any subject to change ,without further notification.

Note:Any specification subject to change without notice;

Powerwell Max (America) series 3PHASE Online HF UPS 10 - 40Kva ,208 - 120Vac ,220 - 127Vac

Inquiry Cart 0