Shenzhen HRD SCI&TECH CO.,Ltd

HRD UPS---Global High-end Power Solutions Expert! Your best trustable OEM/ODM power partner! ISO9001-2015,ISO14001 , ISO18001, TLC, CQC, TUV ,CE certified.

Manufacturer from China
Verified Supplier
16 Years
Home / Products / Online Low Frequency UPS /

Online LF UPS 6-40KVA with PFC function

Online LF UPS 6-40KVA with PFC function

Ask Latest Price
Place of Origin :Shenzhen China
Brand Name :HRD/OEM
Model Number :1KVA -30KVA
Certification :CE,ISO9001
MOQ :10pcs
Packaging Details :1PCS/1CTN,STANDARD FOR EXPORT
Delivery Time :3-4 weeks after down payment
Payment Terms :TT OR LC
Supply Ability :100pcs/day
Price :600-4800USD
Warranty :18months after shipment
Price term :Fob Shenzhen
type :Online LF UPS
technology :DPS controlled
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Online LF UPS 6-40KVA with PFC function

Powersafe series Online LF UPS 1-30kVA

1. System Introduction

PS II Series UPS is a full-digitized with European Cortex-M3 MCU (STM32F103RCT6 )controlled single phase input/single phase output or 3 phase input/single phase output online UPS. It provides reliable, stable, and constant AC power for computer equipment, telecommunication devices, precision equipment/instrument, and network termination equipment (NTE). UPS systems protects all these devices from losing data or information due to power outage, interruption or disruption to truly and comprehensively solve power issues, such as power outage, power surge, voltage sags, temporary over-voltage, temporary under voltage, frequency offset, power disturbances, switching transients, and harmonic wave distortion.

2.Syetem Features

2.1High Performance Index

◆ Advanced SCR Rectifier and IGBT Inverter Technology. Online 1/1 or 3/1 double conversion structure.

◆ Adapt with output isolated transformer technology to fit 200,220,230,240Vac,50/60Hz Grid Systems;

◆ Wide Input Range from Single Phase 160-280Vac,3 Phase 286-475Vac ,50/60 Hz±5%,High Adaptive Capacity to Mains Grid

◆ High Overload Ability -- surge current protection technology to carry sudden impact for 0% to 100% load immediately without transfer to bypass;

◆ Overall Efficiency 85%. 98% under ECO Mode;

◆ Full-digitized Non-master slave parallel redundancy technology. Parallel circumfluence ≤5%;

◆ Intelligent Charging Design. It equips with BAT low/over charged sensor to protect the charger. Real-time diagnosis on Battery status and response data simultaneously;

◆ Large Color Dot-matrix LCD+LED Screen with multi-functional keyboard to check system parameters, such as fault histories, operational statuses self-diagnosis periodically discharge settings, etc.

◆ Battery Self-testing can be done on the LCD directly. Battery Capacity, UPS working mode (Online or ECO) can be set on the screen. All history faults and statistics can be seen on the screen to help user analyze the working summary of the UPS.

◆ Monitoring can be done by WAN/LAN SNMP adapter or Cloud Monitoring Adapter. UPS equips with RS232, USB, EPO ports, and can choose RS485 and Dry-contact as optional accessories.

◆ Front to Rear Ventilation Design to reduce the defective rate of the product.

◆ Smart Size.

2.2. Safe and Reliable

◆ MCU control to operate all power conversion sessions during the operations, which has higher system reliability than traditional UPS systems.

◆ Output Isolated Transformer Built-in. It can reduce impacts and interferences from Load Harmonic Wave Current and N-Wire Voltage.

◆ Special Design on battery connectors to save the shock hazards from mis-operation;

◆ 90% of system components are from international brands. All devices has been aged and fully tested for at least 24 hours before leaving the factory.

3. Rich Optional Accessories

The System can use SNMP Network Adapter, RS485/Dry Contact, USB port,and EPO function to build up a remote control and monitoring system.

4. Application Type

The System is designed for small and medium important equipment systems, such as small and medium commercial network equipment, small data center, important medical equipment, manufacturing process control system and communication equipment.

5. Technical Point

◆ MCU control provides higher system reliability than traditional UPS systems.;

◆ Wide Input Voltage and Frequency Range.;

◆ Non-Master Slave digital parallel redundancy feature;

◆ Advanced Battery Management system;

◆ High Overload Ability;

◆ Dot Matrix Color Screen for friendly ;

◆ Online Double Conversion technology with output isolated transformer

◆ Smart Size compared to the same size of the UPS in the market. All UPS equipped with wheels.

6,Specs

1/1 Phase, 3/1 Phase

Model PS01S/PS01L PS02S/PS02L PS03S/PS03L PS06S/PS06L PS08L PS10L PS150L
Capacity 1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW 6KVA/4.8KW 8KVA/6.4KW 10KVA/8KW 15KVA/12KW
Host Machine Specification
Technology Online Double Conversion
UPS Structure Low Frequency with Output Isolated Transformer
Overall Efficiency (AC-AC ) > 85%
Noise(In 2 meters) < 50dB
Working Temp. -10-40℃
Storage Temp -25-60℃ (Without Batteries)
HumiPSty < 95%Non-Condensing
Safety Standard IEC62040
EMC/EMI Standard EN 50091-2
Parallel Redundancy Available
Protections Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DC Start Available
Generator Compatibility Available
Display

LCD display: Multi-Language with all kinds of messages. Input Output Status, ECO Mode Settings,INV. Temp. TX Status Calendar, Time, Serial Number, Model, Structure, History Logs, Battery Test.

LED Indicators: UPS States Indicator

Mute Auto
Cabinet Standard IP20
Cooling System Intelligent Speed Control Cooling Fan
Elevation <1000M Without Derated
Rectifier Specification
Nominal Voltage 220Vac
Input Voltage Range 160-280Vac
Input Freq. Range 50 Hz±5%(45-65Hz)
Soft-Start >20 Seconds
Output Specification
Output Voltage 220Vac
Output PF 0.8
Output Voltage Regulation 220Vac±1%(Static Load ),220Vac±2% (50~0% Sudden Change)
Output Freq 50Hz±0.1%(BAT Mode)
PSstortion < 1%(100% Linear Full Load),< 3%(100% Non-Linear Full Load)
Frequency Tracking Range 46-54Hz
Output Waveform Pure Sine Wave
Overload 125% More than 1 Min;> 150% More than 300ms 125% More than 10 Mins;> 150% More than 1 Min
Crest Ratio 3∶1
Short-Circuit Circuit Auto Protection,Output Voltage/Current 0
Output Abnormal INV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time 0ms(Static Switch Phase Lock Control Technology)
Static bypass Overload Ability 200%~5 Minutes;1000%~10 Seconds
Frequency Range ±1Hz,±2Hz,±3Hz Adjustable
Manual Maintenance Bypass / Available
Alarm Specification
Alarm Utility Power Fault, BAT Voltage Low, Overload,UPS Fault
Mute Auto
Battery Specification
Type Sealed Lead Acid Maintenance Free
Rated Volts 72Vdc 72Vdc 96Vdc 192Vdc or 96 192Vdc
Charging Current Standard/Built-in Model 1A,Long backup/External Battery Model 5A
BAT Low Shutdown Protection
Communication Specification
Communication Port Rs232 (Std.);/SNMP/RS485/ Dry Contact (Optional Accessory)
Remote Software Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters

Size mm

(W×D×H)

STD. Model 220×510×395 220×610×635 /
EXT Model 220×610×475 220×610×715 310×655×790
Weight Kg 34/25 40/26 46/29 105/76 85 95 125

Note:S in the model refers to standard/built-in battery model. L refers to Long backup/External Battery Model.

1/1 Phase, 3/1 Phase

Model PS60L31 PS100L31 PS150L31 PS200L31 PS300L31
Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW
Host Machine Specification
Technology Online Double Conversion
UPS Structure Low Frequency with Output Isolated Transformer
Overall Efficiency (AC-AC ) > 85%
Noise(In 2 meters) < 50dB
Working Temp. -10-40℃
Storage Temp -25-60℃ (Without Batteries)
Humidity < 95%Non-Condensing
Safety Standard IEC62040
EMC/EMI Standard EN 50091-2
Parallel Redundancy Available
Protections Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DC Start Available
Generator Compatibility Available
PSsplay

LCD display: Multi-Language with all kinds of messages. Input Output Status, ECO Mode Settings,INV. Temp. TX Status Calendar, Time, Serial Number, Model, Structure, History Logs, Battery Test.

LED Indicators: UPS States Indicator

Mute Auto
Cabinet Standard IP20
Cooling System Intelligent Speed Control Cooling Fan
Elevation <1000M Without Derated
Rectifier Specification
Nominal Voltage 380Vac+N+W 3Phase
Input Voltage Range 286-475Vac
Input Freq. Range 50 Hz±5%
Soft-Start >20 Seconds
Output Specification
Output Voltage 220Vac
Output PF 0.8
Output Voltage Regulation 220Vac±1%(Static Load ),220Vac±2% (50~0% Sudden Change)
Output Freq 50Hz±0.1%(BAT Mode)
Distortion < 1%(100% Linear Full Load),< 3%(100% Non-Linear Full Load)
Frequency Tracking Range 46-54Hz
Output Waveform Pure Sine Wave
Overload 125% More than 10 Mins;> 150% More than 1 Min
Crest Ratio 3∶1
Short-Circuit Circuit Auto Protection,Output Voltage/Current 0
Output Abnormal INV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time 0ms(Static Switch Phase Lock Control Technology)
Static bypass Overload Ability 200%~5 Minutes;1000%~10 Seconds
Frequency Range ±1Hz,±2Hz,±3Hz Adjustable
Manual Maintenance Bypass Available
Alarm Specification
Alarm Utility Power Fault, BAT Voltage Low, Overload,UPS Fault
Mute Auto
Battery Specification
Type Sealed Lead Acid Maintenance Free
Rated Volts 192Vdc 384Vdc
Single Group Qty. 16PCS 32PCS
Charging Current Standard/Built-in Model 1A,Long backup/External Battery Model 5A
BAT Low Shutdown Protection
Communication Specification
Communication Port Rs232 (Std.);/SNMP/RS485/ Dry Contact (Optional Accessory)
Remote Software Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters

Size mm

(W×D×H)

EXT Model 310×655×790
Net Weight (Kg) 68 70 98 115 125
Gross Weight (Kg) 76 79 108 125 135

Note:S in the model refers to standard/built-in battery model. L refers to Long backup/External Battery Model.

China Online LF UPS 6-40KVA with PFC function for sale

Online LF UPS 6-40KVA with PFC function

Inquiry Cart 0